ATHENA VALVE


image English
  • image English
  • image Español
  • image lingua italiana
Member Center
Exit
Data is empty
0
qr Code Url

Scan qrcode to view mobile website

  • HOME
  • PRODUCTS
      • Ball Valve
      • Butterfly Valves
      • Check Valve
      • Control Valve
      • Gate Valve
      • Globe Valve
      • Level Gauge
      • Plug Valve
      • Strainer
      • Diaphragm Valve
      • Instrument Valve
  • COMPANY
      • ABOUT US
      • MISSION
      • INDUSTRIES
      • ASSOCIATIONS
      • QUALITY
      • CERTIFICATE
  • PRODUCTS
      • Ball Valve
      • Butterfly Valves
      • Check Valve
      • Control Valve
      • Gate Valve
      • Globe Valve
      • Level Gauge
      • Plug Valve
      • Strainer
      • Diaphragm Valve
      • Instrument Valve
  • PROJECT
  • CONTACT US
  • SEND INQUIRY
  • NEWS
  • DOWNLOAD
  • JOIN US
HOMENEWSNEWS
What Is a Double Check Valve? Working Principle, Applications, and Selection Guide

What Is a Double Check Valve? Working Principle, Applications, and Selection Guide

author: ATHENA GROUP
2026-11-20
{当前产品的产品关键词轮巡使用}
When a pipe bursts in the municipal network, a fire hydrant draws off large volumes of water, or a customer-side pump or a pressurized closed tank raises the pressure, the water in the line may reverse and flow backward. If the downstream side holds fire-protection water, boiler makeup water, or circulating water, contaminated water can flow back into the potable drinking water network, often causing a water-quality incident across an entire district. A double check valve installed at this point of connection acts as a one-way gatekeeper: it allows water to flow forward into the customer while preventing it from backflowing into the public network.

1. What Is a Double Check Valve?

A double check valve, properly designated a double check valve assembly, is a field-testable backflow prevention device used to protect potable water systems from back-siphonage and backpressure backflow; it applies to low-hazard applications.
It is not a single valve. A complete assembly consists of:
  •  Two independently operating spring-loaded check valves installed in series — the two barriers that actually provide protection
  •  Two resilient-seated isolation valves — used to isolate the assembly for testing and maintenance
  •  Four test cocks — the ports through which certified testers connect a differential pressure gauge
Redundant design is the key: even if the first check valve sticks due to debris and develops internal leakage, the second check valve will still close and hold back the reverse flow. This is why a double check valve assembly can be accepted where a single check valve does not qualify.

2. How a Double Check Valve Works

Operation takes place under three conditions:
1. Normal forward supply. Upstream supply pressure pushes the two spring-loaded discs off their seats, allowing water to pass in one direction with only a small head loss.
2. Backpressure backflow. A downstream pump, elevated tank, or pressurized boiler raises the outlet pressure above the inlet pressure; the reverse pressure holds the discs closed, and the two check valves shut off to block the reverse flow.
3. Back-siphonage. A pipe rupture upstream or a water outage creates negative pressure on the inlet side; the springs pull the discs back onto their seats, preventing downstream water from being siphoned back.
The two valves operate independently and are not linked; failure of one does not affect the sealing of the other. This is the fundamental reason it is more reliable than a single check valve.

3. Double Check vs. Reduced Pressure Zone vs. Low-Loss: How to Choose

Many purchasers confuse the three types of backflow preventers; the wrong selection will not pass acceptance by the water authority.
Item Double Check Valve Type Low-Loss Type Reduced Pressure Zone Type
Structure Two check valves, no relief drain Double check valve + automatic intermediate-chamber drain Double check valve + intermediate-chamber relief valve
Intermediate-chamber air break No Yes Yes
Backpressure backflow protection Yes Yes Yes
Back-siphonage protection Not applicable Yes Yes
Hazard level Low Medium High (toxic and harmful)
Head loss Within approx. 4 m ≤3 m, lowest pressure loss Approx. 7 m, highest resistance
Typical applications Small buildings, low-risk terminal points Municipal service connection, secondary water supply Chemical plants, hospitals, pool makeup water

4. Applications

  •  Fire-protection lines that carry potable water only — the most common application of a DCVA; for unmetered fire lines where leakage or unauthorized use must be monitored, a DCDA assembly is used.
  •  Service isolation for low-hazard commercial, public-institution, and light-industrial buildings.
  •  Closed-loop circulating and process water systems — where the backflow cannot cause a health hazard but would deteriorate water quality.
  •  Irrigation systems — subject to local regulations: many regions treat any irrigation system as a health hazard and require an RPZ or PVB instead.

5. Frequently Asked Questions

Q: Can a double check valve replace a reduced pressure zone backflow preventer? No. A double check valve has no intermediate-chamber relief and no air gap, and is approved only for low-hazard backpressure conditions; high-hazard applications such as chemical plants and hospitals must use a reduced pressure zone assembly or an air gap.
Q: Is an ordinary check valve enough? No. After its seal ages, a single check valve may leak; it provides no redundancy and no test ports, and will not be accepted at water-authority inspection.
Q: Does a double check valve require periodic testing? Yes. The seals of the two valves are tested through the test ports; the specific frequency follows the local water utility's regulations, and internal components are replaced when leakage is found.
Q: Is this the same as the ASSE 1015 DCVA? The principle is identical: two independent check valves in series. Domestic units are manufactured to CJ/T 160, North American projects are certified to ASSE 1015, and the certification for export is selected according to the target market.

Conclusion

A double check valve is suitable for low-hazard, backpressure-only applications, where two independent check valves form a redundant seal; high-hazard applications require a reduced pressure zone backflow preventer. The key to selection is to first determine the hazard level, then verify the size, pressure rating, and applicable standard.
Athena Valve is an industrial valve brand of Athena Engineering S.R.L., offering ball valves, gate valves, check valves, and other products. It holds API, CE/PED, and ISO 9001 certifications and supplies the global oil & gas, chemical, water-treatment, and power industries. For selection and pricing of double check valves, check valves, and backflow-prevention piping valves, visit [www.athenavalve.com] or send an email to SALES@ATHENAVALVE.COM; our engineers will provide configuration recommendations based on your operating parameters.

Related News

  • image NACE MR0175 Ball Valves: A Concise Guide to Material Selection and Compliance
    2026-11-14 0
  • image What RTJ Means in a Check Valve
    2026-11-12 0
  • image Valve Pickling Methods
    2026-11-06 0
  • image Concentric vs. Eccentric Butterfly Valve: Which Suits HVAC and Water Systems?
    2026-10-28 0
  • image Slurry Knife Gate Valve
    2026-10-26 0
  • image 2026 Ranking of the World’s Top 10 Ball Valve Brands
    2026-10-24 0
  • image How to Select Part‑Turn, Linear‑Stroke and Multi‑Turn Electric Actuators
    2026-10-23 0
  • image How to Fix a Leaking Ball Valve
    2026-10-16 0
  • image How to Repair a Gate Valve
    2026-10-15 0
  • image Pressure Seal Type Gate Valve for High-Pressure High-Temperature Industrial Isolation
    2026-10-12 0
  • image What Are the Differences Between Forged Valves and Cast Valves?
    2026-10-09 0
  • image Characteristics, Applications and Advantages of Carbon Steel Globe Valves
    2026-09-29 0
  • image Why Are Instrument Valves Indispensable for Industrial Control Systems?
    2026-09-23 0
  • image What is Bi-Directional Valves?
    2026-09-17 0
  • image How Does a Ball Type Check Valve Prevent Pipeline Medium Backflow?
    2026-09-15 0
  • image Selection and Precautions for Natural Gas Valves
    2026-09-10 0
  • image Athena Engineering S.R.L Wraps‑up OGA 2026 Kuala Lumpur
    2026-09-08 0
  • image What is a Gate Valve? What is Its Working Principle?
    2026-09-07 0
  • image T-Type / T-Pattern / Straight Pattern Globe Valve
    2026-09-05 0
  • image Knife Gate Valve vs Wedge Gate Valve: Which Is Better for Your Industrial Piping?
    2026-09-04 0


© 2022-9999 Athena Engineering S.R.L

Email: sales@athenavalve.com

Telephone: +39  02 2247 7576

Parent Company: Athena engineering S.R.L

Company Address: ITALY,20019 SETTIMO MILANESE MI,21/C,VIA LUIGI GALVANI

PRODUCTS

NEWS

COMPANY

DOWNLOAD

PROJECT

CONTACT US

SEND INQUIRY

BACK TO ATHENA GROUP

Dubai subsidiary: Micro Fluid Equipment Trading FZE

Company Address: Jebel Ali Freezone Building, Dubai ,UAE

(270354)